Evidence and recommendation. What is the best technique for neonatal hearing screening?
Abstract Introduction and objective: Clinical question: The otoacoustic emissions (OAE) and automated auditory evoked potentials brainstem response (ABR-A) are acceptable and used in neonatal hearing screening. PICO question: In a newborn [patient], does technique ABR-A against AEE [compared], provide superior detection [result], for neonatal screening hearing loss [intervention]?. Material and Methods: Literature search in PubMed and Cochrane data meta-analysis, clinical trials and general articles, including descriptors "hearing loss", "neonatal screening", "infant, newborn," "evoked potentials, auditory", "otoacoustic emissions". Selected studies in Spanish or English directly comparing one technique over another. Results: The evidence is high for ABR-A because they are more effective (with higher levels of sensitivity and specificity) than the OAE, especially in neonatal intensive care unit and in children at risk of auditory neuropathy. Conclusions: Recommendation: The recommendation is strongly in favor of using ABR-A versus OAS as an initial test in neonatal screening for hearing loss.
- Referencias
- Cómo citar
- Del mismo autor
- Métricas
Dort JC, Tobolski C, Brown D. Screening strategies for neonatal hearing loss: which test is best?. J Otolaryngol. 2000;29(4):206-10. -- PMid:11003070
Doyle KJ, Burggraaff B, Fujikawa S, Kim J. Newborn hearing screening by otoacoustic emissions and automated auditory brainstem response. Int J Pediatr Otorhinolaryngol. 1997;41(2):111-9. http://dx.doi.org/10.1016/S0165-5876(97)00066-9
Trinidad G, Jaúdenes C: Sordera infantil. Del diagnóstico precoz a la inclusión educativa. Guía práctica para el abordaje interdisciplinar. Madrid, Confederación Espa-ola de Familias de Personas Sordas-FIAPAS. 1ª Ed. 2011.
Norton SJ, Gorga MP, Widen JE, Folsom RC, Sininger Y, Cone-Wesson B, et al. Identification of neonatal hearing impairment: evaluation of transient evoked otoacoustic emission, distortion product otoacoustic emission, and auditory brain stem response test performance. Ear Hear. 2000;21(5):508-28. http://dx.doi.org/10.1097/00003446-200010000-00008
http://dx.doi.org/10.1097/00003446-200010000-00013 -- PMid:11059707
Ochoa-Sangrador C. Evidencia y recomendación. Rev. ORL. 2016;7(2). En prensa. Disponible en: http://revistas.usal.es/cinco/index.php/2444-7986/article/view/14019. [citado 5 de junio de 2016]. http://dx.doi.org/10.14201/orl201672.14019
Abdul Wahid SN, Md Daud MK, Sidek D, Abd Rahman N, Mansor S, Zakaria MN. The performance of distortion product otoacoustic emissions and automated auditory brainstem response in the same ear of the babies in neonatal unit. Int J Pediatr Otorhinolaryngol. 2012;76(9):1366-9. http://dx.doi.org/10.1016/j.ijporl.2012.06.008 -- PMid:22770594
Benito-Orejas JI, Ramírez B, Morais D, Almaraz A, Fernández-Calvo JL. Comparison of two-step transient evoked otoacoustic emissions (TEOAE) and automated auditory brainstem response (AABR) for universal newborn hearing screening programs. Int J Pediatr Otorhinolaryngol. 2008;72(8):1193-201. http://dx.doi.org/10.1016/j.ijporl.2008.04.011 -- PMid:18550180
Clarke P, Iqbal M, Mitchell S. A comparison of transient-evoked otoacoustic emissions and automated auditory brainstem responses for pre-discharge neonatal hearing screening. Int J Audiol. 2003;42(8):443-7. http://dx.doi.org/10.3109/14992020309081514 -- PMid:14658852
Freitas VS, Alvarenga Kde F, Bevilacqua MC, Martinez MA, Costa OA. Critical analysis of three newborn hearing screening protocols. Pro Fono. 2009;21(3):201-6. http://dx.doi.org/10.1590/S0104-56872009000300004 -- PMid:19838565
Granell J, Gavilanes J, Herrero J, Sánchez-Jara JL, Velasco MJ, Martín G. Cribado universal de la Hipoacusia neonatal: ¿es más eficiente con potenciales evocados auditivos que con emisiones otoacústicas?. Acta Otorrinolaringol Esp. 2008;59(4):170-5. http://dx.doi.org/10.1016/S0001-6519(08)73288-6
http://dx.doi.org/10.1016/S2173-5735(08)70216-3
Lin HC, Shu MT, Lee KS, Lin HY, Lin G. Reducing false positives in newborn hearing screening program: how and why. Otol Neurotol. 2007;28(6):788-92. http://dx.doi.org/10.1097/MAO.0b013e3180cab754 -- PMid:17948357
van Dyk M, Swanepoel de W, Hall JW 3rd. Outcomes with OAE and AABR screening in the first 48 h--Implications for newborn hearing screening in developing countries. Int J Pediatr Otorhinolaryngol. 2015;79(7):1034-40. http://dx.doi.org/10.1016/j.ijporl.2015.04.021 -- PMid:25921078
Vohr BR, Oh W, Stewart EJ, Bentkover JD, Gabbard S, Lemons J, Papile LA, Pye R. Comparison of costs and referral rates of 3 universal newborn hearing screening protocols. J Pediatr. 2001 Aug;139(2):238-44. http://dx.doi.org/10.1067/mpd.2001.115971 -- PMid:11487750
Doyle KJ, Burggraaff B, Fujikawa S, Kim J. Newborn hearing screening by otoacoustic emissions and automated auditory brainstem response. Int J Pediatr Otorhinolaryngol. 1997;41(2):111-9. http://dx.doi.org/10.1016/S0165-5876(97)00066-9
Trinidad G, Jaúdenes C: Sordera infantil. Del diagnóstico precoz a la inclusión educativa. Guía práctica para el abordaje interdisciplinar. Madrid, Confederación Espa-ola de Familias de Personas Sordas-FIAPAS. 1ª Ed. 2011.
Norton SJ, Gorga MP, Widen JE, Folsom RC, Sininger Y, Cone-Wesson B, et al. Identification of neonatal hearing impairment: evaluation of transient evoked otoacoustic emission, distortion product otoacoustic emission, and auditory brain stem response test performance. Ear Hear. 2000;21(5):508-28. http://dx.doi.org/10.1097/00003446-200010000-00008
http://dx.doi.org/10.1097/00003446-200010000-00013 -- PMid:11059707
Ochoa-Sangrador C. Evidencia y recomendación. Rev. ORL. 2016;7(2). En prensa. Disponible en: http://revistas.usal.es/cinco/index.php/2444-7986/article/view/14019. [citado 5 de junio de 2016]. http://dx.doi.org/10.14201/orl201672.14019
Abdul Wahid SN, Md Daud MK, Sidek D, Abd Rahman N, Mansor S, Zakaria MN. The performance of distortion product otoacoustic emissions and automated auditory brainstem response in the same ear of the babies in neonatal unit. Int J Pediatr Otorhinolaryngol. 2012;76(9):1366-9. http://dx.doi.org/10.1016/j.ijporl.2012.06.008 -- PMid:22770594
Benito-Orejas JI, Ramírez B, Morais D, Almaraz A, Fernández-Calvo JL. Comparison of two-step transient evoked otoacoustic emissions (TEOAE) and automated auditory brainstem response (AABR) for universal newborn hearing screening programs. Int J Pediatr Otorhinolaryngol. 2008;72(8):1193-201. http://dx.doi.org/10.1016/j.ijporl.2008.04.011 -- PMid:18550180
Clarke P, Iqbal M, Mitchell S. A comparison of transient-evoked otoacoustic emissions and automated auditory brainstem responses for pre-discharge neonatal hearing screening. Int J Audiol. 2003;42(8):443-7. http://dx.doi.org/10.3109/14992020309081514 -- PMid:14658852
Freitas VS, Alvarenga Kde F, Bevilacqua MC, Martinez MA, Costa OA. Critical analysis of three newborn hearing screening protocols. Pro Fono. 2009;21(3):201-6. http://dx.doi.org/10.1590/S0104-56872009000300004 -- PMid:19838565
Granell J, Gavilanes J, Herrero J, Sánchez-Jara JL, Velasco MJ, Martín G. Cribado universal de la Hipoacusia neonatal: ¿es más eficiente con potenciales evocados auditivos que con emisiones otoacústicas?. Acta Otorrinolaringol Esp. 2008;59(4):170-5. http://dx.doi.org/10.1016/S0001-6519(08)73288-6
http://dx.doi.org/10.1016/S2173-5735(08)70216-3
Lin HC, Shu MT, Lee KS, Lin HY, Lin G. Reducing false positives in newborn hearing screening program: how and why. Otol Neurotol. 2007;28(6):788-92. http://dx.doi.org/10.1097/MAO.0b013e3180cab754 -- PMid:17948357
van Dyk M, Swanepoel de W, Hall JW 3rd. Outcomes with OAE and AABR screening in the first 48 h--Implications for newborn hearing screening in developing countries. Int J Pediatr Otorhinolaryngol. 2015;79(7):1034-40. http://dx.doi.org/10.1016/j.ijporl.2015.04.021 -- PMid:25921078
Vohr BR, Oh W, Stewart EJ, Bentkover JD, Gabbard S, Lemons J, Papile LA, Pye R. Comparison of costs and referral rates of 3 universal newborn hearing screening protocols. J Pediatr. 2001 Aug;139(2):238-44. http://dx.doi.org/10.1067/mpd.2001.115971 -- PMid:11487750
Benito-Orejas, J. I., & Pardal-Refoyo, J. L. (2016). Evidence and recommendation. What is the best technique for neonatal hearing screening?. Revista ORL, 7(2), 97–102. https://doi.org/10.14201/orl.14680
Most read articles by the same author(s)
- José Ignacio Benito-Orejas, Laura Parra-Morais, Marleny Casasola-Girón, Ramón Cicuéndez-Ávila, Darío Morais-Pérez, María Fe Muñoz-Moreno, Results of applying a safety protocol of the patient with tracheotomy from a critical care unit , Revista ORL: Vol. 13 No. 3 (2022)
- Marleny Casasola-Girón, José Ignacio Benito-Orejas, Felipe Bobillo-de Lamo, Laura Parra-Morais, Ramón Cicuéndez-Ávila, Darío Morais-Pérez, Safety management of the patient with tracheostomy from a critical care unit. , Revista ORL: Vol. 9 No. 1 (2018)
- José Luis Pardal-Refoyo, Evidence and recommendation. Does Harmonic Ultracision offer any advantage in thyroidectomy? , Revista ORL: Vol. 7 No. 4 (2016)
- Patricia Viveros-Díez, José Ignacio Benito-Orejas, Jesús Eduardo Ramírez Salas, María Álvarez Quiñones-Sanz, Victoria Duque-Holguera, María Álvarez-Álvarez, Trichofolliculoma of the external auditory canal, an exceptional case of aggressive presentation , Revista ORL: Vol. 13 No. 1 (2022)
- Luis Miguel Torres-Morientes, Ana Sánchez-Martínez, Ana Fernández-Rodríguez, José Ignacio Benito-Orejas, Darío Morais-Pérez, Partial duplication of the internal yugular vein and its relation with the espinal nerve. Description of two cases. , Revista ORL: Vol. 7 No. 2 (2016)
- José Luis Pardal-Refoyo, Luis Francisco Santiago-Peña, Jesús Javier Cuello-Azcárate, Juan Carlos García-Vázquez, Design of a system for detecting and reporting security incidents and adverse events in thyroid and parathyroid surgery , Revista ORL: Vol. 7 No. 1 (2016)
- Patricia Viveros-Díez, José Ignacio Benito-Orejas, María Álvarez Quiñones-Sanz, Jesús Eduardo Ramírez Salas, Victoria Duque-Holguera, María Álvarez-Álvarez, Trichofolliculoma in the external auditory canal. Bibliographic review , Revista ORL: Vol. 13 No. 1 (2022)
- José Ignacio Benito-Orejas, Ángel Batuecas-Caletrío, Practical guideline for benign paroxysmal positional vertigo: collaboration as way to improve the assistance , Revista ORL: Vol. 8 No. 3 (2017)
- José Luis Pardal-Refoyo, The research question , Revista ORL: Vol. 10 No. 4 (2019)
- Juan Losada-Campa, José Ignacio Benito-Orejas, María San Millán-González, Mariana González-Sosto, Maria Fe Muñoz-Moreno, Jaime Santos-Pérez, Systematic review on the influence of age, gender and seasonal variations on peritonsillar abscess , Revista ORL: Vol. 15 No. 1 (2024)
Downloads
Download data is not yet available.
+
−